The SEC Cellyte ETG series of OPzV VRLA Tubular Gel single cells is a traditional design that complies with International DIN standards. The range is engineered with die cast tubular grids and gelled electrolyte which reduces the need for topping up and makes the product virtually maintenance free. The range also incorporates SEC's industry leading CatVent catalyst technology as standard. This means lower float currents which in turn means reduced gassing, reduced cell heating and reduced positve plate corrosion. The resulting range is perfect for high integrity critical applications including power generation & distribution, telecom and premium renewable energy projects.
The 2V series is available in a wide range of capacities from 100 to 3000 Ah and with a choice of standard or V0 rated flame retardent tough ABS cases. A selection of bespoke racking solutions are also available including designs approved for Seismic Zone 4 installations.
The ETG range is manufactured in SEC's ISO approved factories and is backed by a full 5 year warranty as standard.
Specification Design life
The SEC Cellyte ETG series of OPzV VRLA tubular single
cells are based on traditional design, but incorporate SEC
CatVent™ performance enhancing catalyst technology whilst
still complying with DIN standards. The range is engineered
with die cast tubular spines using a Calcium Tin Lead Alloy. The
gelled electrolyte prevents the need for topping up, making the
product virtually maintenance free.
SEC's industry-leading CatVent™ catalyst technology is fitted
as standard across the whole ETG series. SEC CatVent™
technology enables lower float currents which in turn means
reduced gassing, reduced cell heating, and reduced positive
plate corrosion. These benefits result in longer battery life, and
lower operating temperatures.
The OPzV tubular plate gelled battery
Float life: 20-years in float service
@ 30°C with an approved
catalyst
Cycle life: 3000 cycles @ 50% DOD @
25°C.
Through incorporating SEC CatVent™ technology, the designed
operating temperature is increased to 30oC. Then, the ETG has
been tried and tested over many years in high ambient temperature
regions.
The range is perfect for high-integrity, critical applications including
power generation & distribution, telecom and premium renewable
energy projects.
The 2V series is available in a wide range of capacities from 100
to 3000 Ah and with a choice of tough V0 rated flame retardant
casing. A selection of bespoke racking solutions are also available
including designs approved for Seismic zone-4 installations. The
ETG series is manufactured in SEC's ISO approved factories and
is backed by a full 5-year warranty under float service as standard.
5
IEC 60896-21/22-2004
IEC 61427-2005
DIN 43539-T5 1984
DIN 40742:1999
Eurobat
Product compliance
ISO 9001:2015
ISO 14001:2004
Company accreditation
| 2
Low self-discharge
Spill-proof and leak-proof Long life
Operates in sub-zero climates Minimal gas escape when charging Deep cycle capability
Latest plate formation Explosion-proof safety valve Gelled electrolyte: no stratification
Accepts high charge rate Requires minimum equalisation Negligible gassing: increased safety
Never requires additional water Fitted with CatVentTM catalyst Engineered with international
components
Positive electrode: Tubular design plate with optimised corrosion defense and
creep resistant, Calcium Tin Lead alloy
Negative electrode: Flat plate utilising Lead Calcium low gassing grid Alloy
Float charge voltage: 2.25 - 2.30 vpc ± 1% at 25°C
Cyclic charge voltage: 2.35 - 2.40 vpc ± 1% at 25ºC
Electrolyte: Sulphuric acid/Silica gel
Safety valve: 1-3 psi self-resealing
Separators: Microporous plastic
Terminals: Integral brass insert for M8 Bolt
Electrical: 2V 100Ah - 2V 3000Ah at C/10 to 1.80vpc @ 25°C
Product benefits
"This maintenance-free 2V comes with a new twist: a
recombinant catalyst to reduce float charge and operating
temperature, thereby minimising positive spine corrosion
and water loss to further enhance battery life. The best
just got better."
Dr. Mike McDonagh
SEC Group
| 3
The CatventTM technology reduces self-discharge and plate
corrosion so the battery will last longer. It has a calendar life of
over 20-years in stationary applications and a long shelf life in the
right conditions.
The latest tubular plate formation technology means the battery
will perform for longer in a variety of applications. And the low
resistance Lead alloy in the plates makes for faster recharge.
Designed for deep-discharge, the ETG is a hardy battery that's ideally
suited to renewable energy applications. Its construction and high
purity gelled electrolyte means the ETG does not require watering,
making it maintenance-free. This battery offers peace of mind in
harsh environments for remote and stand-alone applications.
The ETG is spill-proof and leak-proof and features explosionproof
vents as standard. This lowers the risk of accidental fire. The
European designed triple-sealed post system offers enhanced
long term durability and security from leaking, which prohibits
tracking between units and prevents low performance issues.
Shock resistant and suited to higher temperature environments.
Designed to operate at 30°C it will withstand a temperature range
between - 15°C to + 40°C. The ETG will operate at sub-zero
temperatures and has an extended lifetime while stationary cycling
at high temperatures > 25°C.
The ETG has extremely low internal resistance, allowing quick
recharge and operation at cooler temperatures. This makes it
more efficient when your application demands a quick charge/
recharge turnaround
Cell dimensions
Dimensions/ Weights/ Data
SEC
model
type
European
DIN type
Nominal
capacity
C/10
1.80 vpc
Battery
weight
Overall battery dimension Maximum
charging
current
(A)
Short
circuit
current
(A)
Internal
resistance
(mΩ)
No. of
terminal
Unit per
crate *
Crates
per 20'
container
*
Cells
per 20'
container
*
Length Width Height
kg mm mm mm
2-ETG-100 2 OPzV 100 100 13 105 208 393 20 960 1.65 2 24 45 1080
2-ETG-150 3 OPzV 150 150 15 105 208 393 30 1450 1.25 2 24 41 984
2-ETG-200 4 OPzV 200 200 18 105 208 393 40 1600 1.20 2 24 37 888
2-ETG-250 5 OPzV 250 250 22 126 208 393 50 2000 1.10 2 24 30 720
2-ETG-300 6 OPzV 300 300 26 147 208 393 60 2400 1.00 2 24 26 624
2-ETG-350 5 OPzV 350 350 29 126 208 509 70 2800 0.90 2 24 24 576
2-ETG-420 6 OPzV 420 420 34 147 208 509 84 3600 0.80 2 24 20 480
2-ETG-500 7 OPzV 490 500 39 168 208 509 100 4200 0.73 2 24 18 432
2-ETG-600 6 OPzV 600 600 46 147 208 684 120 4800 0.62 2 12 29 348
2-ETG-700 7 OPzV 700 700 57 193 212 684 140 5600 0.45 4 8 30 240
2-ETG-800 8 OPzV 800 800 62 193 212 684 160 6400 0.28 4 8 30 240
20 diameter insert
paired with M8 bolt
Colour of case and cover: grey (427U )
SEC CatVentTM catalyst
SEALED VRLA GEL
ETG SERIES
Rating: 2V 900Ah C/10 @ 25°C
Float Voltage: 2.25vpc 1% @ 20-25°C
Max Charge Voltage: 2.35vpc 1% @ 20-25°C
SEC-2-ETG-900
Length
Width
Height
Epoxy seal
(red for +
blue for -)
Plastic at ring
Rubber o-ring
Lead terminal post
with brass insert
Plastic screw cap
to secure the at plastic
washer and o-ring
Integral brass insert
for stainless steel Bolt
* Shipping details are for reference only. | 5
Capacity
Ampere hour at 25°C
SEC
model type
European
DIN type
Discharge ampere hour at 25ºC
End volts/
Cell
Discharge time in hours
1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 120hr
2-ETG-100 2 OPzV 100 1.85 44.9 60.8 70.1 76.4 79.8 83.4 88.8 93.5 107 115 123 126
1.80 50.5 66.8 76.2 80.0 86.0 87.0 95.2 100 113 120 127 129
1.75 52.0 68.6 77.9 82.0 87.8 88.7 96.8 102 115 124 131 134
2-ETG-150 3 OPzV 150 1.85 67.3 91.2 105 115 120 125 133 140 161 173 185 188
1.80 75.8 100 114 120 129 131 143 150 169 180 191 193
1.75 78.0 103 117 123 132 133 145 152 173 185 197 201
2-ETG-200 4 OPzV 200 1.85 89.7 122 140 153 160 167 178 187 215 230 246 252
1.80 101 134 152 160 172 174 190 200 226 240 254 258
1.75 104 137 156 164 176 177 194 203 230 247 263 268
2-ETG-250 5 OPzV 250 1.85 112 152 175 191 200 209 222 234 268 288 308 314
1.80 126 167 191 200 215 218 238 250 283 300 318 323
1.75 131 172 195 205 219 222 242 254 288 309 329 335
2-ETG-300 6 OPzV 300 1.85 135 182 210 229 239 251 266 281 322 346 370 377
1.80 152 200 229 240 258 261 286 300 338 360 381 387
1.75 158 206 234 246 263 266 290 305 346 371 394 402
Cell dimensions
Dimensions/ Weights/ Data
SEC
model
type
European
DIN
type
Nominal
capacity
C/10
1.80 vpc
Battery
weight
Overall battery dimension Maximum
charging
current
(A)
Short
circuit
current
(A)
Internal
resistance
(mΩ)
No. of
terminal
Unit per
crate *
Crates
per 20'
container
*
Cells
per 20'
container
*
Length Width Height
kg mm mm mm
2-ETG-900 8 OPzV 800 900 70 235 212 684 180 7200 0.36 4 8 28 224
2-ETG-1000 10 OPzV
1000
1000 78 235 212 684 200 8000 0.26 4 8 26 208
2-ETG-1200 12 OPzV
1200
1200 92 277 212 684 240 9600 0.45 4 8 22 176
2-ETG-1500 12 OPzV
1500
1500 113 277 212 834 300 12000 0.23 4 8 18 144
2-ETG-1750 14 OPzV
1750
1750 134 400 212 810 350 13300 0.26 6 6 20 120
2-ETG-1875 15 OPzV
1850
1875 145 400 212 810 375 14700 0.25 6 6 19 114
2-ETG-2000 16 OPzV
2000
2000 153 400 212 810 400 16000 0.32 6 6 18 108
2-ETG-2250 18 OPzV
2250
2250 172 489 212 810 450 18000 0.30 8 4 23 92
2-ETG-2500 20 OPzV
2500
2500 193 489 212 810 500 20000 0.28 8 4 21 84
2-ETG-3000 24 OPzV
3000
3000 226 576 212 810 600 24000 0.23 8 4 18 72
| 6
Capacity
Ampere hour at 25°C
SEC
model type
European
DIN type
Discharge ampere hour at 25ºC
End volts/
Cell
Discharge time in hours
1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 120hr
2-ETG-350 5 OPzV 350 1.85 157 210 243 267 278 292 310 325 376 403 431 440
1.80 176 230 264 280 299 305 331 350 396 420 445 451
1.75 183 238 270 287 305 311 337 356 403 432 460 469
2-ETG-420 6 OPzV 420 1.85 188 252 292 321 333 351 371 393 451 484 517 528
1.80 212 278 318 336 359 365 398 420 475 504 533 542
1.75 220 284 324 344 366 373 405 427 484 518 552 563
2-ETG-500 7 OPzV 490 1.85 219 294 339 374 388 409 434 459 526 564 604 616
1.80 247 324 369 392 419 426 464 490 554 588 622 632
1.75 257 332 378 400 427 435 472 498 564 605 644 657
2-ETG-600 6 OPzV 600 1.85 267 354 411 458 471 501 526 562 643 691 739 755
1.80 301 390 447 480 510 522 564 600 678 720 762 774
1.75 313 400 456 492 520 532 574 609 691 742 789 805
2-ETG-700 7 OPzV 700 1.85 312 413 480 535 550 584 614 655 751 806 862 880
1.80 351 453 522 560 590 609 658 700 791 840 889 903
1.75 366 467 533 574 604 621 669 711 806 864 920 939
2-ETG-800 8 OPzV 800 1.85 356 472 549 611 630 666 702 749 859 922 986 1006
1.80 401 518 597 640 675 696 752 800 904 960 1016 1032
1.75 418 534 609 656 690 708 765 813 922 989 1050 1073
2-ETG-900 9 OPzV 900 1.85 401 531 615 688 705 750 792 843 966 1037 1109 1132
1.80 452 583 672 720 760 783 848 900 1017 1080 1140 1161
1.75 470 599 686 738 779 798 856 918 1037 1112 1180 1207
2-ETG-1000 10 OPzV 1000 1.85 445 590 684 764 785 834 880 937 1073 1152 1230 1258
1.80 502 648 747 800 845 870 944 1000 1130 1200 1270 1290
1.75 522 666 762 820 865 887 952 1020 1152 1236 1310 1342
2-ETG-1200 12 OPzV 1200 1.85 535 708 822 916 940 1002 1056 1120 1288 1382 1478 1509
1.80 602 778 894 960 1015 1044 1128 1200 1356 1440 1520 1548
1.75 626 800 915 984 1035 1062 1144 1220 1382 1483 1577 1608
2-ETG-1500 12 OPzV 1500 1.85 666 872 1017 1146 1165 1253 1312 1400 1610 1728 1848 1884
1.80 750 958 1107 1200 1260 1305 1400 1500 1694 1800 1905 1932
1.75 781 984 1131 1230 1285 1331 1424 1520 1728 1853 1970 2012
2-ETG-1750 14 OPzV 1750 1.85 777 1016 1187 1336 1360 1462 1526 1636 1879 2016 2156 2196
1.80 875 1116 1289 1400 1470 1523 1640 1750 1978 2100 2220 2256
1.75 911 1148 1317 1435 1495 1553 1656 1776 2016 2163 2300 2348
2-ETG-1875 15 OPzV 1875 1.85 833 1089 1271 1432 1458 1566 1632 1750 2013 2160 2310 2358
1.80 938 1196 1380 1500 1575 1631 1752 1875 2119 2250 2380 2419
1.75 976 1230 1412 1536 1603 1662 1776 1900 2160 2318 2460 2516
2-ETG-2000 16 OPzV 2000 1.85 888 1162 1356 1528 1555 1668 1744 1870 2147 2304 2460 2516
1.80 1000 1276 1473 1600 1680 1740 1872 2000 2260 2400 2540 2580
1.75 1041 1312 1506 1640 1710 1775 1896 2030 2305 2472 2629 2683
2-ETG-2250 18 OPzV 2250 1.85 999 1306 1526 1719 1750 1878 1966 2106 2415 2592 2770 2971
1.80 1125 1436 1658 1800 1890 1956 2104 2250 2543 2700 2858 3048
1.75 1171 1476 1695 1844 1925 1997 2136 2286 2592 2779 2958 3168
2-ETG-2500 20 OPzV 2500 1.85 1110 1452 1695 1910 1945 2088 2184 2340 2684 2880 3080 3300
1.80 1250 1596 1842 2000 2100 2175 2336 2500 2825 3000 3175 3384
1.75 1301 1640 1884 2050 2140 2219 2376 2540 2880 3090 3286 3516
2-ETG-3000 24 OPzV 3000 1.85 1332 1742 2031 2292 2335 2506 2616 2810 3216 3456 3696 3768
1.80 1500 1914 2211 2400 2520 2610 2800 3000 3384 3600 3810 3870
1.75 1561 1968 2262 2460 2565 2662 2848 3050 3456 3708 3940 4020
| 7
Current
Ampere at 25°C
SEC
model type
European
DIN type
Discharge amps at 25ºC
End volts/
Cell
Discharge time in hours
1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 120hr
2-ETG-100 2 OPzV 100 1.85 44.9 30.4 23.4 19.0 16.0 13.9 11.1 9.35 4.46 2.40 1.23 1.05
1.80 50.5 33.8 25.4 20.5 17.2 14.9 11.9 10.0 4.71 2.50 1.27 1.08
1.75 52.0 34.8 26.0 21.0 17.5 15.2 12.1 10.1 4.80 2.57 1.31 1.12
2-ETG-150 3 OPzV 150 1.85 67.3 45.6 35.0 28.7 23.9 20.8 16.6 14.0 6.71 3.60 1.85 1.57
1.80 75.8 50.0 38.0 30.0 25.8 21.8 17.9 15.0 7.06 3.75 1.91 1.61
1.75 78.0 51.5 38.9 30.8 26.3 22.2 18.1 15.2 7.20 3.85 1.97 1.68
2-ETG-200 4 OPzV 200 1.85 89.7 60.8 46.7 38.2 31.9 27.8 22.2 18.7 8.95 4.79 2.46 2.10
1.80 101 66.8 50.7 40.0 34.4 29.0 23.8 20.0 9.42 5.00 2.54 2.15
1.75 104 68.5 51.9 41.0 35.1 29.5 24.2 20.3 9.6 5.15 2.63 2.23
2-ETG-250 5 OPzV 250 1.85 112 76.0 58.3 47.8 39.9 34.8 27.8 23.4 11.2 6.00 3.08 2.62
1.80 126 83.5 63.5 50.0 43.0 36.3 29.8 25.0 11.8 6.25 3.18 2.69
1.75 131 85.8 64.9 51.3 43.8 37.0 30.3 25.4 12.0 6.44 3.29 2.79
2-ETG-300 6 OPzV 300 1.85 135 91.0 70.0 57.3 47.8 41.8 33.3 28.1 13.4 7.20 3.70 3.14
1.80 152 100 76.2 60.0 51.6 43.5 35.7 30.0 14.1 7.50 3.81 3.23
1.75 158 103 77.9 61.5 52.6 44.3 36.3 30.5 14.4 7.73 3.94 3.35
2-ETG-350 5 OPzV 350 1.85 157 105 81.0 66.8 55.5 48.7 38.7 32.5 15.7 8.40 4.31 3.67
1.80 176 115 88.0 70.0 59.8 50.8 41.4 35.0 16.5 8.75 4.45 3.76
1.75 183 119 90.0 71.8 61.0 51.8 42.1 35.6 16.8 9.01 4.60 3.91
2-ETG-420 6 OPzV 420 1.85 188 126 97.2 80.2 66.5 58.5 46.4 39.3 18.8 10.1 5.17 4.40
1.80 212 139 106 84.0 71.8 60.8 49.7 42.0 19.8 10.5 5.33 4.52
1.75 220 142 108 86.0 73.1 62.1 50.6 42.7 20.2 10.8 5.52 4.69
2-ETG-500 7 OPzV 490 1.85 219 147 113 93.5 77.6 68.2 54.2 46.8 21.9 11.8 6.04 5.13
1.80 247 162 123 98.0 83.7 71.0 58.0 50.0 23.1 12.3 6.22 5.27
1.75 257 166 126 100 85.3 72.5 59.0 50.8 23.5 12.6 6.44 5.48
2-ETG-600 6 OPzV 600 1.85 267 177 137 115 94.2 83.5 65.8 56.2 26.8 14.4 7.39 6.29
1.80 301 195 149 120 102 87.0 70.5 60.0 28.3 15.0 7.62 6.45
1.75 313 200 152 123 104 88.7 71.7 60.9 28.8 15.5 7.89 6.71
2-ETG-700 7 OPzV 700 1.85 312 207 160 134 110 97.4 76.8 65.5 31.3 16.8 8.62 7.33
1.80 351 227 174 140 118 102 82.3 70.0 33.0 17.5 8.89 7.53
1.75 366 234 178 144 121 104 83.6 71.1 33.6 18.0 9.20 7.83
2-ETG-800 8 OPzV 800 1.85 356 236 183 153 126 111 87.8 74.9 35.8 19.2 9.86 8.38
1.80 401 259 199 160 135 116 94.0 80.0 37.7 20.0 10.2 8.60
1.75 418 267 203 164 138 118 95.6 81.3 38.4 20.6 10.5 8.94
2-ETG-900 9 OPzV 900 1.85 401 266 205 172 141 125 99.0 84.3 40.3 21.6 11.1 9.43
1.80 452 292 224 180 152 131 106 90.0 42.4 22.5 11.4 9.68
1.75 470 300 229 185 156 133 107 91.8 43.2 23.2 11.8 10.1
2-ETG-1000 10 OPzV 1000 1.85 445 295 228 191 157 139 110 93.7 44.7 24.0 12.3 10.5
1.80 502 324 249 200 169 145 118 100 47.1 25.0 12.7 10.8
1.75 522 333 254 205 173 148 119 102 48.0 25.8 13.1 11.2
2-ETG-1200 12 OPzV 1200 1.85 535 354 274 229 188 167 132 112 53.7 28.8 14.8 12.6
1.80 602 389 298 240 203 174 141 120 56.5 30.0 15.2 12.9
1.75 626 400 305 246 207 177 143 122 57.6 30.9 15.8 13.4
2-ETG-1500 12 OPzV 1500 1.85 666 436 339 287 233 209 164 140 67.1 36.0 18.5 15.7
1.80 750 479 369 300 252 218 175 150 70.6 37.5 19.1 16.1
1.75 781 492 377 308 257 222 178 152 72.0 38.6 19.7 16.8
2-ETG-1750 14 OPzV 1750 1.85 777 508 396 334 272 244 191 164 78.3 42.0 21.6 18.3
1.80 875 558 430 350 294 254 205 175 82.4 43.8 22.2 18.8
1.75 911 574 439 359 299 259 207 178 84.0 45.1 23.0 19.6
| 8
Current
Ampere at 25°C
SEC
model type
European
DIN type
Discharge amps at 25ºC
End volts/
Cell
Discharge time in hours
1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 120hr
2-ETG-1875 15 OPzV 1875 1.85 833 545 424 358 292 261 204 175 83.9 45.0 23.1 19.7
1.80 938 598 460 375 315 272 219 188 88.3 46.9 23.8 20.2
1.75 976 615 471 384 321 277 222 190 90.0 48.3 24.6 21.0
2-ETG-2000 16 OPzV 2000 1.85 888 581 452 382 311 278 218 187 89.5 48.0 24.6 21.0
1.80 1000 638 491 400 336 290 234 200 94.2 50.0 25.4 21.5
1.75 1041 656 502 410 342 296 237 203 96.0 51.5 26.3 22.4
2-ETG-2250 18 OPzV 2250 1.85 999 653 509 430 350 313 246 211 101 54.0 27.7 24.8
1.80 1125 718 553 450 378 326 263 225 106 56.3 28.6 25.4
1.75 1171 738 565 461 385 333 267 229 108 57.9 29.6 26.4
2-ETG-2500 20 OPzV 2500 1.85 1110 726 565 478 389 348 273 234 112 60.0 30.8 27.5
1.80 1250 798 614 500 420 363 292 250 118 62.5 31.8 28.2
1.75 1301 820 628 513 428 370 297 254 120 64.4 32.9 29.3
2-ETG-3000 24 OPzV 3000 1.85 1332 871 677 573 467 418 327 281 134 72.0 37.0 31.4
1.80 1500 957 737 600 504 435 350 300 141 75.0 38.1 32.3
1.75 1561 984 754 615 513 444 356 305 144 77.3 39.4 33.5
Power
Watts/cell at 25°C
SEC
model type
European
DIN type
Discharge data watts/cell at 25ºC
End volts/
Cell
Discharge time in hours
1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 120hr
2-ETG-100 2 OPzV 100 1.85 85.9 58.8 45.5 37.5 31.4 27.5 22.1 18.6 8.95 4.81 2.51 2.14
1.80 95.6 64.1 49.2 39.0 33.7 28.5 23.5 19.8 9.42 5.00 2.58 2.19
1.75 97.0 65.1 49.8 39.6 34.1 28.8 23.7 20.1 9.52 5.12 2.66 2.27
2-ETG-150 3 OPzV 150 1.85 129 88.1 68.2 56.3 47.1 41.2 33.0 27.9 13.5 7.23 3.77 3.20
1.80 144 96.0 73.6 58.5 50.5 42.9 35.3 29.8 14.1 7.50 3.88 3.27
1.75 145 97.7 74.6 59.4 51.1 43.2 35.5 29.9 14.3 7.65 4.00 3.40
2-ETG-200 4 OPzV 200 1.85 172 118 91.0 74.9 62.8 55.0 44.1 37.3 18.0 9.62 5.01 4.28
1.80 191 128 98.1 78.0 67.4 57.0 47.1 39.7 18.8 10.0 5.17 4.37
1.75 194 130 100 79.2 68.2 57.5 47.4 40.0 19.1 10.2 5.34 4.53
2-ETG-250 5 OPzV 250 1.85 214 147 114 93.7 78.6 68.8 55.1 46.7 22.4 12.0 6.27 5.33
1.80 239 160 123 97.5 84.2 71.4 58.9 49.6 23.6 12.5 6.47 5.47
1.75 244 163 124 99.0 85.1 72.1 59.3 50.0 23.8 12.8 6.68 5.67
2-ETG-300 6 OPzV 300 1.85 258 176 136 112 94.2 82.6 66.1 56.0 26.9 14.5 7.54 6.40
1.80 288 192 148 117 101 85.5 70.6 59.5 28.2 15.0 7.75 6.56
1.75 295 195 149 119 102 86.4 71.1 60.0 28.6 15.4 8.00 6.80
2-ETG-350 5 OPzV 350 1.85 300 203 158 131 109 96.2 76.9 64.8 31.4 16.9 8.78 7.47
1.80 333 221 170 137 117 99.9 81.8 69.4 33.0 17.5 9.05 7.65
1.75 341 226 173 139 118 101 82.5 70.1 33.3 17.9 9.34 7.94
2-ETG-420 6 OPzV 420 1.85 360 244 189 157 131 116 92.1 78.4 37.7 20.2 10.5 8.96
1.80 402 267 205 164 141 120 98.3 83.3 39.6 21.0 10.8 9.19
1.75 410 270 207 166 142 121 99.2 84.0 40.1 21.4 11.2 9.52
2-ETG-500 7 OPzV 490 1.85 419 284 220 183 153 135 108 91.5 44.0 23.6 12.3 10.5
1.80 468 311 238 191 164 140 115 97.2 46.2 24.5 12.7 10.7
1.75 479 315 242 193 166 141 116 98.0 46.7 25.0 13.1 11.1
Operating temperature
Design operating
temperature
30°C with an approved
catalyst
Limit for charging -10 to +50°C
Limit for discharging -15 to +50°C
Limit for storage -20 to +50°C
Charging method
Float charge voltage at
25ºC
2.25 - 2.30 vpc with
temperature compensation
Cyclic charge voltage at
25ºC
2.35 - 2.40 vpc with
temperature compensation
Float charge temperature
compensation factor
-3 mV/cell/oC above 25oC
+3 mV/cell/oC below 25oC
Cyclic charge temperature
compensation factor
-5 mV/cell/oC above 25oC
+5 mV/cell/oC below 25oC
| 9
Power
Watts/cell at 25°C
SEC
model type
European
DIN type
Discharge data watts/cell at 25ºC
End volts/
Cell
Discharge time in hours
1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 120hr
2-ETG-600 6 OPzV 600 1.85 511 342 267 225 186 165 131 112 53.8 28.9 15.1 12.8
1.80 570 374 289 234 200 171 139 119 56.5 30.0 15.5 13.1
1.75 584 380 292 238 202 173 141 120 57.2 30.7 16.0 13.6
2-ETG-700 7 OPzV 700 1.85 597 399 312 262 217 193 153 131 62.8 33.7 17.6 14.9
1.80 665 435 337 273 231 200 163 139 65.9 35.0 18.1 15.3
1.75 683 443 341 277 235 202 164 140 66.7 35.7 18.7 15.9
2-ETG-800 8 OPzV 800 1.85 681 456 357 300 248 219 174 149 71.8 38.5 20.1 17.1
1.80 759 497 385 312 264 228 186 159 75.3 40.0 20.7 17.5
1.75 780 507 389 317 268 230 187 160 76.3 40.9 21.3 18.1
2-ETG-900 9 OPzV 900 1.85 767 513 400 337 278 247 197 168 80.8 43.4 22.6 19.2
1.80 856 560 434 351 298 257 210 179 84.8 45.0 23.2 19.7
1.75 877 568 439 356 303 259 210 181 85.8 46.0 24.0 20.4
2-ETG-1000 10 OPzV 1000 1.85 851 570 444 375 309 275 219 187 89.7 48.2 25.1 21.4
1.80 951 622 482 390 331 285 233 198 94.2 50.0 25.8 21.9
1.75 974 632 487 396 336 288 233 201 95.3 51.1 26.6 22.7
2-ETG-1200 12 OPzV 1200 1.85 1023 684 534 449 370 330 262 223 108 57.8 30.1 25.6
1.80 1140 747 577 468 398 342 279 238 113 60.0 30.9 26.2
1.75 1167 759 585 475 402 345 280 240 114 61.4 32.0 27.2
2-ETG-1500 12 OPzV 1500 1.85 1274 843 661 562 459 413 326 279 135 72.3 37.6 32.0
1.80 1421 920 715 585 494 428 346 298 141 75.0 38.7 32.7
1.75 1457 934 723 594 499 432 349 299 143 76.7 40.0 34.0
2-ETG-1750 14 OPzV 1750 1.85 1486 982 771 655 536 482 379 326 157 84.3 43.9 37.3
1.80 1657 1071 832 683 576 499 405 347 165 87.5 45.2 38.2
1.75 1699 1089 842 693 581 504 406 350 167 89.5 46.7 39.7
2-ETG-1875 15 OPzV 1875 1.85 1594 1053 826 702 574 516 405 349 168 90.3 47.1 40.0
1.80 1777 1148 891 731 617 534 433 372 177 93.8 48.4 41.0
1.75 1820 1167 903 742 623 540 435 374 179 95.9 49.9 42.6
2-ETG-2000 16 OPzV 2000 1.85 1699 1123 881 749 613 550 433 373 180 96.3 50.1 42.7
1.80 1894 1225 951 780 658 570 463 397 188 100 51.7 43.7
1.75 1941 1245 963 792 664 577 465 400 191 102 53.4 45.4
2-ETG-2250 18 OPzV 2250 1.85 1911 1262 991 843 690 619 488 420 202 108 56.4 50.4
1.80 2131 1379 1071 878 741 641 520 446 212 113 58.1 51.7
1.75 2184 1401 1084 891 748 649 523 450 214 115 60.0 53.6
2-ETG-2500 20 OPzV 2500 1.85 2123 1403 1101 937 766 688 542 467 224 120 62.7 56.0
1.80 2368 1532 1189 975 823 713 577 496 235 125 64.6 57.4
1.75 2426 1556 1205 990 831 721 582 500 238 128 66.7 59.5
2-ETG-3000 24 OPzV 3000 1.85 2548 1684 1319 1124 920 826 650 560 269 145 75.3 64.0
1.80 2841 1837 1428 1170 987 855 692 595 282 150 77.5 65.6
1.75 2911 1868 1446 1188 996 865 698 600 286 153 80.0 68.0